A SERVICE OF

logo

5
© 2007 Hunter Fan Company 41663-01 10/24/2007

 Press this button to turn ‘on’ the ionizer. When the ionizer is ‘on’, the
green light near the button will be illuminated.
 Rotate the Speed Control knob to set the desired speed. A set-
ting of zero (0) indicates that the unit is off, one (1) is low speed, two (2) is medium
speed, and three (3) is high speed. The fan speed can be adjusted at any time.
 The lter counter is designed to optimize the perfor-
mance of the air purifer by reminding you when to
change the HEPAtech Filter and pre-lter.
 The HEPAtech Filter
indicator is located at the top of the calendar ring. To
set the HEPAtech Filter counter, rotate the calendar
ring to align the month that you installed the lter with
the top indicator. Since the lter is designed for 6
months use, the two indicators will serve as reminders
to change the lter every 6 months.
 The inner knob of the lter
counter is the pre-lter counter. To use, align the
knob with the month that you installed the pre-lter.
The replace symbol on the inner knob points to the
month in which you should install a new pre-lter. The pre-lter is designed for
three months of usage.

1. Clean the outside of the unit with a soft, damp cloth. The front grill can be
removed and cleaned in soapy water.
2. At least every 90 days, open the front grill, remove the carbon pre-lter, and
replace it. This is necessary to maintain proper odor-removing and overall
ltration performance. If necessary, it can be changed more often. Mark the
new lter installation sticker included with the new carbon pre-lter. Be sure
to remove any plastic wrapping that may be on the new lter before you place
it into the Air Purier.
3. While replacing the pre-lter, you should view the condition of the HEPAtech
Filter. Compare the lter to the color coded chart that is on the inside of the
housing. If the lter matches the dark color on the chart, you should remove
the lter and replace it with a new lter. Be sure to remove any plastic wrap-
ping that may be on the new lter before you place it into the Air Purier.
Figure 3 - Calendar Knob