![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/e/3c/e3c14052-d811-4a1e-830d-47087b13c6e8/e3c14052-d811-4a1e-830d-47087b13c6e8-bg5e.png)
94 Troubleshooting
Indicator-Related Symptoms
Symptom / Error Action in Sequence
Indicator incorrectly remains
off or on, but system runs
correctly
Reconnect the inverter board
Inverter board
System board
Power-Related Symptoms
Symptom / Error Action in Sequence
Power shuts down during
operation
Power source (battery pack and power adapter).
See “Power System Check” on page 88.
Battery pack
Power adapter
Hard drive & battery connection board
System board
The system doesn’t power-
on.
Power source (battery pack and power adapter).
See “Power System Check” on page 88.
Battery pack
Power adapter
Hard drive & battery connection board
System board
The system doesn’t power-
off.
Power source (battery pack and power adapter).
See “Power System Check” on page 88.
Hold and press the power switch for more than 4
seconds.
System board
Battery can’t be charged See “Check the Battery Pack” on page 88.
Battery pack
System board
PCMCIA-Related Symptoms
Symptom / Error Action in Sequence
System cannot detect the
PC Card (PCMCIA)
PCMCIA slot assembly
System board
PCMCIA slot pin is
damaged.
PCMCIA slot assembly