6 Section 61150090L1-5A, Issue 1 61150090L1-5A
9. Hoist the cabinet to an upright position and
center it over the pad.
CAUTION
The minimum internal bend radius for cable
stubs is nine inches.
10. At this time, on the cable stub model, the cable
stubs should be fed through their designated
conduit or other route per craft plan.
11. Lower the cabinet with attached brackets onto
the pad ensuring the four bottom bracket
5/8 inch bolt holes align with the pad fastener
arrangement. Secure with customer supplied
fasteners. Continue feeding the cable stubs as the
cabinet is lowered.
12. On the ground lug on the cabinet bottom next to
the spare cable penetration attach an
appropriately sized (6 AWG) ground cable to the
most direct path to ground. Ground cable and
connectors are customer supplied.
CAUTION
Without positive ground surge protection is
lost.
13. After the cabinet is secured to the pad the front
and back security access covers can be installed
on the pad mounting brackets using the included
fasteners. Tighten to 10-15 in-lbs. Install with
the access cover lip facing in and against the
cabinet’s bottom panel. See Figure 4.
13. If lifting details are to be removed, replace the
fasteners removed in step 4 ensuring the sealing
washers are installed next to the cabinet side
panels.
Pole Mount Installation
Pole mounting has two configurations:
Mounted to a single pole on either the left or
right side panel.
H-frame where the cabinet is supported by a
frame arrangement at either the left or right side
panel.
The pole-mount or H-frame support structure must
bear the weight of a fully equipped cabinet (200 Lbs).
The weight and the distance the cabinet will be
installed above the ground determines the type of pole
configuration to be selected. Refer to Figure 7 for
pole mount access clearances.
1. At the installation site remove all packaging
material enclosing the cabinet.
2. Remove and set aside the Mounting Hardware
Kit. Verify kit contents per Table 3.
3. The cabinet is bolted to two boards running
across the wood box frame. Remove the screws
securing the two boards to the wood box frame.
Figure 7. Pole Mount Dimensions
Pad mounted stud*
(4 places)
*Customer supplied
Mounting
Bracket
nut*
split
washer*
flat
washer*
bolt torque:
100-110 in-lbs
Pad arrangement is representative
sealing washer
5/8" dia
Figure 6. Pad Mounting Bracket Installation
33"
top to bottom
brackets included
63"
overall with
doors open