An example of the format for setting the script file variables is as follows:
SET AUDIOENV 14
SET AUDIOSTHD 1
SET AUDIOSTHS 2
EXPANENHS If this system variable is 1, then the
system changes the default
noise-reduction algorithm operating
in the transmit path, and uses an
actual expander algorithm. If the
value is 0 or not specified, then the
system takes the normal
noise-reduction algorithms.
EXPANENHD If this system variable is 1, then the
system changes the default
noise-reduction algorithm operating
in the transmit path changes, and
uses an actual expander algorithm.
If the value is 0 or not specified,
then the system takes the normal
noise-reduction algorithms.
Parameter Name Default Value Status Description and Value Range