![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/e5/3e588437-0572-4010-a3d1-60ac6d8bf5eb/3e588437-0572-4010-a3d1-60ac6d8bf5eb-bgbf.png)
724-746-5500 | blackbox.com
Page 191
Chapter 7: Command-Line Management
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use this command to to set time zone.
3. Command Syntax:
clock timezone TIMEZONE
TIMEZONE Specifies the time zone. (Please refer the Appendix B)
4. Example:
The following example sets time zone (Canada/Yukon):
switch_a(config)#clock timezone YST9YDT
switch_a(config)#
Polling Interval:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use this command to specify the polling interval.
3. Command Syntax:
ntp polling-interval MINUTE
MINUTE <1-10080> The polling interval. Enter a value in the range 1 to 10080 minutes.
4. Example:
The following example specifies the polling interval 60 minutes:
switch_a(config)#ntp polling interval 60
switch_a(config)#
Daylight Saving Mode:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use this command to enable daylight saving.
Use no clock summer-time command to disable daylight saving.