Command inputs
After the connection has been established, you must log onto the unit to access
the main menu. Other submenus and functions can be accessed using the
on-screen commands.
– If necessary, turn off the local echo so that entered values are not repeated
on the display.
– Enter one command at a time.
– When you have entered a value (such as an IP address), check the charac-
ters you have entered before pressing the [ENTER] key to transfer the values
to the unit.
Assigning an IP Address
To use a VideoJet 8008 or VideoJet 8004 in your network, you must assign it an
IP address that is valid for your network.
The following default address is preset at the factory: 192.168.0.1
– Start a terminal program such as HyperTerminal.
–First enter ? and then service as the user name. The terminal program dis-
plays the main menu.
– Enter command i to open the IP menu.