UNITSIZE
NOMINAL COOLING CAPACITY (ton)
NOMINAL HEATING CAPACITY (Btu)
OPERATING WEIGHT (Ib)
(kg)
COMPRESSORS
Quantity
REFRIGERANT: PURON (R-410A)
Quantity (Ib)
(kg)
REFRIGERANT METERING DEVICE
Size
Part Number
OUTDOOR FAN
Nominal Cfm
Diameter (in.)
(mm)
Motor Hp (Rpm)
OUTDOOR COIL
Rows...Fins/in,
Face Area (sq ft)
INDOOR COIL
Rows...Fins/in,
Face Area (sq ft)
INDOOR FAN
Nominal Airflow (Cfm)
Comfort
Efficiency
Max
Furnace (gas ht.) airflow-Low Stage
Furnace (gas ht.) airflow-High Stage
Size (in.)
(ram)
Motor HP (RPM)
FURNACE SECTION*
Burner Orifice No. (Qty._Drill Size)
Natural Gas
HIGH-PRESSURE SWITCH (peig)
Cut-out
Reset (Auto)
HIGH-PRESSURE SWITCH 2 (peig)
(Compressor Solenoid)
Cut-out
Reset (Auto)
LOSS-OF-CHARGE /
LOW-PRESSURE SWITCH
(Liquid Line) (psig)
Cut-out
Reset (auto)
RETURN-AIR FILTERS Throwaway
(in.)1-
(ram)
Table 1--Physical Data (Con't) - Unit 48XL
048090 048115 060115 060130
4 4 5 5
90,000 115,000 115,000 130,000
521 521 572 572
236 236 259 259
048130 060090
4 5
130,000 90,000
521 572
236 259
2-Stage Scroll
1
15.3 15.3 15.3 15.8 15.8 15.8
6.9 6.9 6.9 7.2 7.2 7.2
TXV
4Ton 4Ton 4Ton 5Ton 5Ton 5Ton
EA36YD 149 EA36YD 149 EA36YD 149 EA36YD 159 EA36YD 159 EA36YD 159
3300 3300 3300 3300 3300 3300
22 22 22 22 22 22
559 559 559 559 559 559
1/4 (1100) 1/4 (1100) 1/4 (1100) 1/3 (1110) 1/3 (1110) 1/3 (1110)
2...21 2...21 2...21 2...21 2...21 2...21
19.4 19.4 19.4 23.3 23.3 23.3
3...17 3...17 3...17 4...17 4...17 4...17
5.7 5.7 5.7 5.7 5.7 5.7
Variable based on Comfort Rollback(see Userlnterfaceinstructionsfor moreinformation).
1400 1400 1400 1750 1750
1600 1600 1600 2000 2000
1255
1875
11x10
279x254
3/4
845
1300
11x10
279x254
1
1215
1910
11x10
279x254
1
815
1385
11x10
279x254
3/4
1215
1885
11x10
279x254
3/4
1750
2000
1255
1920
11x10
279x254
1
3...38 3...33 3...31 3...38 3...33 3...31
670 ± 10
470 ± 25
565 ± 15
455 ± 15
23 ± 5
55 ± 5
24x36xl
610x914x25
*Based on altitude of 0 to 2000 ft (0 to 610 m).
1-Recommended filter sizes for field-installed air filter grilles mounted on the wall or ceiling of the conditioned structure. Required filter sizes shown are based on
the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450
ft/minute for high-capacity type. Air filter pressure drop for non-standard filters must not exceed 0.08 IN. W.C.
Rig and Place Unit
Rigging and handling of this equipment can be hazardous for
many reasons due to the installation location (roofs, elevated
structures, etc.).
Only trained, qualified crane operators and ground support staff
should handle and install this equipment.
When working with this equipment, observe precautions in the
literature, on tags, stickers, and labels attached to the equipment,
and any other safety precautions that might apply.
Training for operators of the lifting equipment should include, but
not be limited to, the following:
1. Application of the lifter to the load, and adjustment of the
lifts to adapt to various sizes or kinds of loads.
2. Instruction in any special operation or precaution.
3. Condition of the load as it relates to operation of the lifting
kit, such as balance, temperature, etc.
Follow all applicable safety codes. Wear safety shoes and work
gloves.
7
Provide Clearances
The required minimum service clearances are shown in 5 and 6.
Adequate ventilation and outdoor air must be provided. The
outdoor fan draws air through the outdoor coil and discharges it
through the top fan grille. Be sure that the fan discharge does not
recirculate to the outdoor coil. Do not locate the unit in either a
corner or under an overhead obstruction. The minimum clearance
under a partial overhang (such as a normal house overhang) is 48
in. above the unit top. The maximum horizontal extension of a
partial overhang must not exceed 48 in. (1219 mm).
IMPORTANT: Do not restrict outdoor airflow. An air restriction
at either the outdoor-air inlet or the fan discharge may be
detrimental to compressor life.
Do not place the unit where water, ice, or snow from an overhang
or roof will damage or flood the unit. Do not install the unit on
carpeting or other combustible materials. Slab-mounted units
should be at least 4 in. (102 mm) above the highest expected water
and runoff levels. Do not use unit if it has been under water.