Table 4 — Electrical Data — 50EJ,EK,EW,EY024-048 (cont)
UNIT
SIZE
NOMINAL
VOLTAGE
(3 Ph 60 Hz)
VOLTAGE
RANGE
COMPRESSOR
OFM IFM
POWER
EXHAUST
ELECTRIC
HEAT*
POWER SUPPLY
No. 1 No. 2
Min Max RLA LRA RLA LRA Qty Hp FLA (ea) Hp FLA FLA LRA kW FLA MCA MOCP†
034
208/230 187 254 57.1 266 57.1 266 2 1 5.3
10
30.8/
28.0
— — — — 169.9/167.1 225/200
23.6 41.6 — — 193.5/190.7 250/225
— — 29/36 75.1/ 86.6 169.9/167.1 225/200
23.6 41.6 29/36 75.1/ 86.6 193.5/190.7 250/225
— — 59/72 150.1/173.2 188.6/208.2 225/225
23.6 41.6 59/72 150.1/173.2 218.1/237.7 250/250
15
46.2/
42.0
— — — — 185.3/181.1 225/225
23.6 41.6 — — 208.9/204.7 250/250
— — 29/36 75.1/ 86.6 185.3/181.1 225/225
23.6 41.6 29/36 75.1/ 86.6 208.9/204.7 250/250
— — 59/72 150.1/173.2 207.9/225.7 250/250
23.6 41.6 59/72 150.1/173.2 237.4/255.2 275/275
20
59.4/
54.0
— — — — 198.5/193.1 250/250
23.6 41.6 — — 222.1/216.7 275/250
— — 29/36 75.1/ 86.6 198.5/193.1 250/250
23.6 41.6 29/36 75.1/ 86.6 222.1/216.7 275/250
— — 59/72 150.1/173.2 224.4/240.7 275/275
23.6 41.6 59/72 150.1/173.2 253.9/270.2 300/300
460 414 508 25.6 120 25.6 120 2 1 2.7
10 14
— — — — 77.0 100
12.6 23.6 — — 89.6 110
— — 36 43.3 77.0 100
12.6 23.6 36 43.3 89.6 110
— — 72 86.6 104.1 110
12.6 23.6 72 86.6 119.9 125
15 21
— — — — 84.0 100
12.6 23.6 — — 96.6 110
— — 36 43.3 84.0 100
12.6 23.6 36 43.3 96.6 110
— — 72 86.6 112.9 125
12.6 23.6 72 86.6 128.6 150
20 27
— — — — 90.0 110
12.6 23.6 — — 102.6 125
— — 36 43.3 90.0 110
12.6 23.6 36 43.3 103.6 125
— — 72 86.6 120.4 125
12.6 23.6 72 86.6 136.1 150
575 518 632 20.5 96 20.5 96 2 1 2.4
10 11
— — — — 61.9 80
12.6 23.6 — — 74.5 90
— — 36 34.6 61.9 70
12.6 23.6 36 34.6 74.5 90
— — 72 69.3 83.0 90
12.6 23.6 72 69.3 98.8 100
15 17
— — — — 67.9 80
12.6 23.6 — — 80.5 100
— — 36 34.6 67.9 80
12.6 23.6 36 34.6 80.5 100
— — 72 69.3 90.5 100
12.6 23.6 72 69.3 106.3 110
20 22
— — — — 72.9 90
12.6 23.6 — — 85.5 100
— — 36 34.6 72.9 90
12.6 23.6 36 34.6 86.6 100
— — 72 69.3 96.8 110
12.6 23.6 72 69.3 112.5 125
20