COLORdash™ Par User Manual 14 9/4/2008 12:09 PM
The figure above shows 6 fixtures connected in series with corresponding addresses.
Each fixture has {ID ON} in the fixture’s settings. You must set the {Range} settings
in the controller to [006] before accessing {Effect} programs.
The figure above shows 9 fixtures
connected in series with corresponding
addresses. Each fixture has {ID ON} in
the fixture’s settings. You must set the
{Range} settings in the controller to
[009] before accessing {Effect}
programs.
The figure above shows 9 fixtures connected in
series. Three rows comprised of 3 fixtures are
addressed identically. Each fixture has {ID ON} in
the fixture’s settings. You must set the {Range}
settings in the controller to [003] before accessing
{Effect} programs.
Repeat Row Block Application
COLORcon™ Setup
1. FIXTURE CONTROL PANEL SETUP
Activate ID addressing in each fixture by setting panel function {ID ON/OFF} to ON.
{MENU} {Settings) {ID ON/OFF} [ON]
Set ID addresses in each fixture by setting panel function {ID address} to
incremental values. (I.e. 1,2,3,4,5,6,etc…)
{MENU} {Settings} {ID address} [01 ~ 66]
It is not necessary to set the DMX address.
2. CONTROLLER SETUP
When using the {Effect program} function, it is necessary to set the {Settings}
{Range} setting, which is the quantity of fixtures in series.
{MENU} {Settings} {Range} [ (No. of fixtures) ]