XML8110 OPERATION
Problem Cause Action
Unit will not turn on
(no power)
Yellowwirenotconnectedorincorrect
voltageRedwirenotconnectedor
incorrectvoltage
Checkconnectionsforproper
voltage(11~16VDC)
Blackwirenotconnected Checkconnectiontoground
Fuseblown Replacefuse
Unit has power
(but no sound)
Speakerwiresnotconnected Checkconnectionsatspeakers
Oneormorespeakerwirestouching
eachotherortouchingchassisground
Insulateallbarespeakerwires
fromeachotherandchassis
ground
Unit blows fuses
Yelloworredwiretouchingchassis
ground
Checkforpinchedwire
Speakerwirestouchingchassisground Checkforpinchedwire
Incorrectfuserating Usefusewithcorrectrating