THE INSTALLATION SPACE
Water and Electrical Locations
The opening must be prepared with the
electrical and water supply located as shown.
The cutout depth must be 24″
The refrigerator will project forward, slightly
beyond adjacent cabinets, depending on
your installation.
Additional Specifications
• A 120 volt, 60Hz, 15 or 20 amp power
supply is required. An individual properly
grounded branch circuit or circuit breaker
is recommended. Install a properly
grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must
be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through
the floor or rear wall. The water line
installed should be 1/4″ O.D. copper tubing
between the cold water line and water
connection location. The line should be
long enough to extend to the front of the
refrigerator. Installation of an easily
accessible shutoff valve in the water line is
required.
DIMENSIONS AND CLEARANCES
Allow minimum clearances for Freezer
door (Dimension A) and Fresh Food door
(Dimension B) for a full 130° door swing
and to allow for drawer removal.
Four inch (4″) minimum clearance is required
when door swing is adjusted to 90°. If the 90°
door stop position is used, drawer access is
maintained, but drawer removal is restricted.
See illustrations, pages 18 and 19, to
determine door swing interaction with
adjacent cabinets or countertops.
*The finished cutout width must be:
41-1/2″ for 42″ models