A SERVICE OF

logo

Model 16 English Instruction Sheet
Page
14
Function Range Resolution Accuracy Burden Voltage
(50 Hz to 400
Hz)
0 to 200
µ
A0.1
µ
A
±
(2% + 3 counts) <5 mV/
µ
A
0 to 200
µ
A0.1
µ
A
±
(1% + 2 counts) <5 mV/
µ
A
Function
Overload
Protection
1
Input Impedance (Nominal)
600V rms
>5 M
<100 pF
VCheck and LoZ = >2 k
<200 pF (ac coupled)
2
600V rms
>10M
<100 pF
VCheck and LoZ = >2 k
<200 pF
2
Common Mode Rejection
Ratio (1 k
Unbalanced)
Normal Mode Rejection
600V rms >60 dB at dc 50 or 60 Hz
600V rms >100 dB at dc, 50 or 60 Hz >50 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Full Scale Voltage
To 4.0 M
40 M
600V rms <1.5V dc <450 mV dc <1.5V dc
600V rms 2.4-3.0V dc 2.400V dc
Short Circuit Current
600V rms <500
µ
A
600V rms
0.95 mA (typical)
1. 3 x 10
6
V Hz maximum
2.
2 k
input impedance up to 50V. Impedance increases with input voltage to
>300 k
at 600V.
MIN MAX Recording Accuracy and Response Time
Specified accuracy of the measurement function
±
12 digits in dc for changes
>200 ms in duration (
±
40 digits in ac). Typical 100 ms response to 80%.
Example 1: This would mean
±
1.2
°
when recording temperature.
Example 2: This would mean
±
12
µ
A when recording
µ
A or
±
12A if used with a
dc amp probe (with a mV input).