1. Move the roller (102) by turning the motor fan
until the roller reaches the 6 o’clock position.
Figure 9 Roller in 6 O’Clock Position
2. Install one end of the hose (103) through the
rear port of the pump housing on the left hand
side when looking at it from the front. Extend
the hose 2-3 in. (51–76 mm) beyond the pump
housing (1).
3. Slide the hose clamp (104) over the hose and
install the barbed tting (105).
4. Position the hose clamp about 1/4 in. (6 mm)
from the end of the hose. Using the 24L497
Clamping Tool, tighten the clamp to secure the
hose onto the barbed tting.
Figure 10 Tighten the Clamp
5. Cut the excess band, then atten the end with a
rubber mallet.
Figure 11 Flatten the Band
6. Install the screws (115) and torque to 115 in-lb
(13.0 N•m).
7. Loop the hose (103) 360 degrees and pass the
other end through the front port on the right hand
side of the pump housing (1). Assemble the
barbed tting (105) and clamp (104) as explained
in steps 3–6.
8. Turn the roller (102) to the 12 o’clock position
and push the hose into the pump housing. Use a
rubber mallet if the hose is difcult to seat.
9. Return the roller (102) to the 6 o’clock position,
compressing the hose. It is critical that the roller
is at the bottom of the pump to ensure the correct
capacity of hose lube. Reinstall the motor fan
cover.
NOTICENOTICE
NOTICE
The roller must be returned to the 6 o’clock
position before installing the front cover.
Failure to do so will result in overlling of the
pump with hose lube.