A SERVICE OF

logo

Part Number
437508-B21
Operational AC Input Voltage
Range (Vrms)
90 - 264
Frequency Range (Nominal) (Hz)
47 to 63 (50/60)
Nominal Input Voltage (Vrms)
100 120 208 220 230 240
Max Rated Output Wattage Rating
800 900 1200 1200 1200 1200
Nominal Input Current (A rms)
9.50 8.80 6.70 6.30 6.05 5.80
Max Rated Input Wattage Rating
(Watts)
964 1071 1412 1412 1412 1412
Max. Rated VA (Volt-Amp)
984 1093 1441 1441 1441 1441
Nominal Efficiency (%)
86 87 88 88 88 88
Power Factor
0.98 0.98 0.98 0.98 0.98 0.98
Leakage Current (mA)
.42 .50
0.86 0.92 0.96 1.00
Maximum Inrush Current (A peak)
30 30 100 100 100 100
Maximum Inrush Current duration
(msec)
5 5 5 5 5 5
NOTES:
To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool
located at URL:
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
.
To drill down to calculators:
Click on: "ProLiant Servers"
Click on the Server of interest. Example: DL580 G5
Click on: "Power Calculator" link. (You may need to scroll down to see it)
There are certain Dual-Core, lowline, max configurations that are not supported. All highline configurations are
supported. Consult the Power Calculator to determine if your lowline configuration is supported.
NOTE:
If customers require a local power cord, they can check the power cord matrix for the appropriate county specific
sku. Please see the following power cord matrix for details:
http://www.hp.com/go/powercordmatrix
QuickSpecs
HP ProLiant DL580 Generation 5
Power Specifications
DA - 12770 Worldwide QuickSpecs — Version 18 — 7.18.2008
Page 43