10 - 6
Beeper Duration - Good Read *Normal Beep
BEPBIP0
3-2
Short Beep
BEPBIP1
3-2
LED - Good Read Off
BEPLED0
3-2
*On
BEPLED1
3-2
LED - Indicator State *Off
BEPPOI0
3-2
On
BEPPOI1
3-2
Number of Beeps - Good Read *1
BEPRPT1
3-2
Range 1 - 9
BEPRPT#
3-2
Good Read Delay *No Delay
DLYGRD0
3-3
Short Delay (500 ms)
DLYGRD500
3-3
Medium Delay (1000 ms)
DLYGRD1000
3-3
Long Delay (1500 ms)
DLYGRD1500
3-3
User-Specified Good Read Delay Range 0 - 30,000 ms
DLYGRD#####
3-3
Manual/Serial Trigger *Manual/Serial Trigger Mode
TRGMOD0
3-3
Read Time-Out
(0 - 300,000 ms) *30,000
TRGSTO####
3-4
Scan Stand Scan Stand Mode
TRGMOD4
3-4
Scan Stand Symbol
FNC3
3-4
Presentation Presentation Mode
TRGMOD3
3-4
Presentation Sensitivity Range 0-20 (*1)
TRGPMS##
3-5
Hands Free Time-Out Range 0 - 300,000 ms
TRG-
PTO######
3-5
Reread Delay Short (500 ms)
DLYRRD500
3-5
*Medium (750 ms)
DLYRR750
3-5
Long (1000 ms)
DLYRRD1000
3-5
Extra Long (2000 ms)
DLYRRD2000
3-5
User-Specified Reread Delay Range 0 - 30,000 ms
DLYRRD#####
3-6
LED Power Level Off
PWRLDC0
3-6
Low (50%)
PWRLDC50
3-6
*High (100%)
PWRLDC100
3-6
Imager Time-Out Range 0 - 999,999 ms
(*60,000 ms)
SDRTIM#####
#
3-6
Aimer Delay 200 milliseconds
SCNDLY200
3-7
400 milliseconds
SCNDLY400
3-7
*Off (no delay)
SCNDLY0
3-7
User-Specified Aimer Delay Range 0 - 4,000 ms
SCNDLY####
3-7
Aimer Mode Off
SCNAIM0
3-7
Interlaced
SCNAIM2
3-7
Selection
Setting
* Indicates default
Serial
Command
# Indicates a
numeric entry
Page