![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/9c/c9c938dc-08e0-4f18-bf1d-a5d513c93ed8/c9c938dc-08e0-4f18-bf1d-a5d513c93ed8-bg2e.png)
2 - 16
Parity provides a means of checking character bit patterns for validity.
Default = None.
RS-232 Receiver Time-Out
The unit stays awake to receive data until the RS-232 Receiver Time-Out
expires. A manual or serial trigger resets the time-out. When an RS-232
receiver is sleeping, a character may be sent to wake up the receiver and reset
the time-out. A transaction on the CTS line will also wake up the receiver. The
receiver takes 300 milliseconds to completely come up. Change the RS-232
receiver time-out by scanning the bar code below, then scanning digits from the
inside back cover of this manual, then scanning Save. The range is 0 to 300
seconds.
Default = 0 seconds (no time-out - always on).
7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity None
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop, Parity Odd
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop Parity None
* 8 Data, 1 Stop, Parity None
8 Data, 1 Stop, Parity Even
8 Data, 1 Stop, Parity Odd