A SERVICE OF

logo

TK-7150
42
Item Condition
Measurement Adjustment
Specifications/Remarks
Test-
equipment
Unit Terminal PartsUnit Method
ADJUSTMENT
14. DQT 1) CH-SIG : 1-7
Power meter
Rear ANT Front
Selector
±0.75kHz ±0.05kHz
deviation Select DQT_Dev_ _✽✽✽ Deviation panel panel knob
• Wide in tuning mode meter
PTT : ON
Deviation meter filter AF VTVM Front MIC
HPF : OFF AG panel
LPF : 3kHz
Oscilloscope
De-emphasis : OFF
• Narrow 2) [PF5] key : Set the narrow ±0.35kHz ±0.05kHz
n_ _
DQT_Dev_ _✽✽✽
in tuning mode
PTT : ON
15. LTR code 1) CH-SIG : 1-2 1.00kHz ±0.05kHz
deviation Select LTR_Dev_ _✽✽✽
• Wide in tuning mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis : OFF
• Narrow 2) [PF5] key : Set the narrow 0.75kHz ±0.05kHz
n_ _
LTR_Dev_ _✽✽✽
in tuning mode
PTT : ON
16. DTMF 1) CH-SIG : 1-9 ±3.0kHz ±0.1kHz
deviation Select DTMF_Dev_✽✽✽
• Wide in tuning mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
• Narrow 2) [PF5] key : Set the narrow ±1.5kHz ±0.1kHz
n_ _
DTMF_Dev_✽✽✽
in tuning mode
PTT : ON
17. MSK 1) CH-SIG : 1-12 ±3.0kHz ±0.1kHz
deviation Select MSK_Dev_ _✽✽✽
• Wide in tuning mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
• Narrow 2) [PF5] key : Set the narrow ±1.5kHz ±0.05kHz
n_ _
MSK_Dev_ _✽✽✽
in tuning mode
PTT : ON