![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/b9/0b9e63c1-f375-4a2e-acb6-cab6772f2b95/0b9e63c1-f375-4a2e-acb6-cab6772f2b95-bg4f.png)
Diagnostic Error Code FRU/Action
170-198-XXX
Voltage Sensor(s) test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a disc”
on page 656
3. Go to “Undetermined problems” on page
80
170-199-XXX
Voltage Sensor(s) test failed, cause unknown
1. See “Undetermined problems” on page
80
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a disc”
on page 656
3. Replace component under function test
170-250-XXX
170-251-XXX
Voltage Sensor(s) Voltage limit error
1. Power supply
2. System board
170-254-XXX
Voltage Sensor(s) Voltage Regulator Module
error
1. Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
175-000-XXX
Thermal Sensor(s) Test Passed
No action
175-0XX-XXX
Thermal Sensor(s) failure
1. Flash system
2. System board
175-195-XXX
Thermal Sensor(s) Test aborted by user
Information only
Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
175-198-XXX
Thermal Sensor(s) test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a disc”
on page 656
3. Go to “Undetermined problems” on page
80
Chapter 7. Symptom-to-FRU index 73