![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/a6/9a6590d8-d220-4ff2-a611-8f7fb01dd656/9a6590d8-d220-4ff2-a611-8f7fb01dd656-bg40.png)
1100 Fan
For access, remove this FRU:
v “1010 Battery pack” on page 46
v “1090 Thermal module slot cover” on page 57
2
3
1
1
1
For MT 0689
Step Screw (quantity) Color Torque
1 M2.5 × 5 mm, flat-head, nylon-coated (3) Black 0.392 Nm
(4
kgfcm)
For MT 0768
Step Screw (quantity) Color Torque
1 M2.5 × 6 mm, flat-head, nylon-coated (3) Silver 0.392 Nm
(4
kgfcm)
For MT 0769
Step Screw (quantity) Color Torque
1 M2.5 × 6 mm, pan-head, nylon-coated (3) Silver 0.392 Nm
(4
kgfcm)
When installing: Make sure that the fan connector is attached firmly.
Removing and replacing a FRU
58 MT 0689, 0768, and 0769