112
Understanding MFP messages
53 Unformatted flash
detected
The MFP detects unformatted flash
memory.
Touch Continue to clear the message and
continue printing. The MFP continues with
normal operations except for flash operations.
Reformat the flash to allow flash operations.
If the error message reappears, the flash
memory may be defective and require
replacing.
54 Network [x] software
error
The MFP cannot establish
communications with a specified
installed network port. x indicates the
number of the specified port.
Touch Continue to clear the message and
continue printing. The job may not print
correctly.
The MFP disables attempts to communicate
through the network interface. No data may
be sent or received.
Reset the MFP.
Program new firmware for the network
interface.
54 Serial option [x]
error
The MFP detects a serial error, such
as framing, parity, or overrun on the
specified optional serial port. x is the
number of the optional serial port.
Make sure the serial link is set up correctly,
and the appropriate cable is in use.
Make sure the serial interface parameters
(protocol, baud, parity, and data bits) are set
correctly on the printer and host computer.
Touch Continue to clear the message and
continue processing the print job; however
the print job may not print correctly.
Turn the MFP off and then on to reset it.
54 Standard network
software error
The MFP firmware detects an
installed network port, but cannot
establish communication with it.
Touch Continue to clear the message and
continue printing. The job may not print
correctly.
The MFP disables attempts to communicate
through the network interface. No data may
be sent or received.
Reset the MFP.
Program new firmware for the network
interface.
56 Parallel port [x]
disabled
A status request occurs over the
parallel port, but the parallel port is
disabled.
Touch Continue. The MFP discards any data
received on the parallel port.
Touch Reset Active Bin to reset the active bin
for a linked set of bins.
56 Serial port [x]
disabled
The MFP receives data across a
serial port, but the port is disabled.
Touch Continue. The MFP discards any data
received on the serial port.
Touch Reset Active Bin to change to another
linked bin.
56 Standard parallel
port disabled
The message appears when a status
is requested through the parallel port,
but the port is disabled.
Touch Continue to clear the message.
The MFP discards any data received through
the parallel port.
Make sure the Parallel Buffer menu item is
not set to Disabled.
56 Standard USB port
disabled
The MFP receives data through a
USB port, but the USB port is
disabled.
Touch Continue. The printer discards any data
received through the USB port.
Make sure the USB Buffer menu item is not set
to Disabled.
Touch Reset Active Bin to change to another
linked bin.
Message Meaning Action