3 kW 120 VAC 3 kW 120 VAC
9 kW
120 VAC
LOAD
3 kW 120 VAC
STACKING OPTIONS
OutBack FXs can be stacked in one of  ve di erent con gurations:
1. OutBack Parallel
2. Classic Series
3. OutBack Series
4. OutBack Series/Parallel
5. 3-Phase
Note: Although stacking 10 FXs is possible, OutBack’s AC hardware only accommodates con gurations
of two, four, or eight FXs. A system with eight FXs would require two AC Input/Output Bypass (IOB)
Assembly Kits or installing an external manual bypass; ten FXs would require three IOB kits or an
external manual bypass.
1. Outback Parallel
2-10 FXs are wired to the same 120VAC output leg or phase.
The Slave FXs can be programmed to remain at di erent power levels (“Silent” or “On” depending on
the need) to save energy; the Slaves will come on when the power demand requires them.
This power-saving system is fully automatic and works with or without a MATE connected to the
system, although a MATE is required to program the components. Without a MATE, the user cannot
reprogram.
The AC input (generator or grid) must be 120VAC.
2. Classic Series
Two FXs are wired to two 120VAC output
legs producing 240VAC between them.
Each FX powers one leg and acts
independently of the other, but both
combine when 240VAC is required for a load.
The AC input (generator or grid) must be 240
split-phase VAC.
3 kW
120 VAC
Leg 2
3 kW 120 VAC
3 kW 120 VAC
LOAD
3 kW
120 VAC
Leg 1
6 kW
120 VAC
Leg 1
and
Leg 2
or
3 kW
120 VAC
Leg 2