3.10 Connection of 2.4 GHz Portable Stations
Installation Manual 193
4. After setting the DIP switches, connect the CS to an AC adaptor/battery box using a power supply
adaptor.
Notes
• The AC adaptor should be connected to a vertically oriented or floor-mounted AC outlet. Do not
connect the AC adaptor to a ceiling-mounted AC outlet, as the weight of the adaptor may cause it
to become disconnected.
• If the Power Supply Select switch is set to ON in step 3, connect the CS to an AC adaptor/battery
box. If it is set to OFF, connect the CS to a CSIF/DLC/DHLC card (KX-TDA0151/KX-TDA0152
only).
5. Install the CS temporarily for the site survey. Install the CS at least 2 m above the floor, keeping the
antennas in the upright position.
KX-TDA0151/KX-TDA0152 KX-TDA0141/KX-TDA0142
To AC Adaptor (KX-A11/KX-TCA1)/
Battery Box (PSZZTD142CE)
Power Supply Adaptor
(PSZZ1TDA0142)
Modular
Telephone Cord
To CSIF/DLC/DHLC card
Modular
To AC Adaptor (KX-A11/KX-TCA1)/
Battery Box (PSZZTD142CE)
Power Supply Adaptor
(PSZZ1TDA0142)
Modular