While the POS. /SIZE display is active, if either the N button on the remote control is pressed at any time or the ACTION
(
) button is pressed during “NORMALIZE”, then all adjustment values (except “CLOCK PHASE” and “DOT CLOCK”)
are returned to the factory settings.
Helpful Hint ( /
NORMALIZE
Normalization)
H-POS Adjust the horizontal position. V-POS Adjust the vertical position.
H-SIZE Adjust the horizontal size. V-SIZE Adjust the vertical size.
CLOCK
PHASE
(During RGB and PC input signal)
Eliminate the À ickering and distortion.
DOT
CLOCK
(During RGB and PC input signal)
Periodic striped pattern interference (noise) may occur when a striped pattern is displayed. If this happens,
adjust so that any such noise is minimized.
OVER
SCAN
Turn image over scan ON/OFF.
Con¿ gurable signals are as follows:
525i, 525p, 625i, 625p, 750/60p, 750/50p (Component Video, DVI, HDMI)
ON OFF
Notes:
“OFF” is effective during only “FULL” aspect mode.
When “OFF” is set, “H-SIZE” and “V-SIZE” cannot be adjusted.
1:1 PIXEL
MODE
Adjusts the display size when 1125i or 1125p signal is input.
Notes:
“ON” is effective during only “FULL” aspect mode.
Select ON when you would like to replay 1920 × 1080 input signal.
Applicable input signal;
1125 (1080) / 50i · 60i · 24sF · 24p · 25p · 30p · 50p · 60p
Select OFF when À ickering is shown around the image.
H-SIZE and V-SIZE cannot be adjusted when ON is selected.
OFF ON