![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/e/6f/e6f56975-dc1a-4371-b46f-4620ecf1f793/e6f56975-dc1a-4371-b46f-4620ecf1f793-bg27.png)
59042-01 A 4-1
Section 4
Installation
This section describes how to install and configure the SANbox2-8c switch. It also
describes how to load new firmware and how to recover a disabled switch.
4.1
Site Requirements
The following items are required for the installation of a SANbox2-8c switch:
■ Fabric management workstation
■ Power requirements
■ Environmental conditions
4.1.1
Fabric Management Workstation
SANbox Manager requires a management workstation equipped as described in
Table 4-1 :
Telnet workstations require an RJ-45 Ethernet port and an operating system with
a Telnet client.
4.1.2
Switch Power Requirements
Operating voltage requirements are as follows:
90 to 137 Vac; 47 to 63 Hz
180 to 264 Vac; 47 to 63 Hz
Table 4-1. Management Workstation Requirements
Operating System
■ Windows® NT, 2000, 95/98
■ Linux® 6.2 Red Hat®
■ Solaris™
Memory 128 MB or more
Disk Space 150 MB per installation
Processor 300 MHz or faster
Hardware CD-ROM drive, RS-232 serial port, RJ-45 Ethernet port
Internet Browser Microsoft® Internet Explorer® or Netscape Navigator®