53
E
Specications
n
Product Specications
Model PN-L802B
LCD component
80" Class [80 inch (203.2cm) diagonal] TFT LCD
Max. resolution (pixels)
1920 x 1080
Max. colors
Approx. 1.06 billion colors
Pixel pitch
0.923 mm (H) × 0.923 mm (V)
Viewing angle
160° right/left/up/down (contrast ratio ≥ 10)
Screen active area inch (mm)
69-3/4 x 39-1/4 (1771.2 x 996.3)
Computer input signal
Digital (DVI 1.0 standard-compliant), Analog RGB (0.7 Vp-p) [75
Ω
]
Sync signal
Horizontal/vertical separate (TTL: positive/negative), Sync-on-green,
Composite sync (TTL: positive/negative)
Video color system
NTSC (3.58MHz)/NTSC (4.43MHz)/PAL/PAL-60/SECAM
Plug and play
VESA DDC2B
Power management
VESA DPMS, DVI DMPM
Input terminals
PC/AV
Digital
HDMI x 1
PC
Analog
Mini D-sub 15 pin, 3 rows x 1
Audio
3.5 mm mini stereo jack x 1
Serial (RS-232C)
D-sub 9 pin x 1
When PN-ZB01
(optional) is
attached
PC/AV
Digital
DVI-D 24 pin (HDCP compatible) x 1
PC
Analog
BNC
*
1
*
2
x 1
AV
Composite video
BNC x 1
S-video
x 1
Component BNC (Y, Cb/Pb, Cr/Pr) *
1
x 1
Audio
RCA pin (L/R) x 2
Output terminals
Audio
RCA pin (L/R) x 1
Serial (RS-232C)
D-sub 9 pin x 1
When PN-ZB01
(optional) is
attached
PC/AV
Digital
DVI-D 24 pin x 1
External speaker 7 W + 7 W
[6
Ω
]
LAN terminal
[
When PN-ZB01 (optional) is attached
]
10 BASE-T/100 BASE-TX
Speaker output 7 W + 7 W
Touch Panel
Detection method Infrared camera method
Detection area inch (mm)
69-3/4 x 39-1/4 (1771.2 x 996.3)
PC connector USB (1.1 compliant)
Power supply Supplied from USB
Touch pen Ultrasonic communication method
Power requirement AC 100 V - 240 V, 2.9 A, 50/60 Hz
Operating temperature
*
3
*
4
41°F to 95°F (5°C to 35°C)
Operating humidity
*
4
20% to 80% (no condensation)
Power consumption
(Maximum / input signal waiting mode
*
5
/ standby
mode
*
6
)
255 W / 1.0 W / 1.0 W
Power consumption
[
When PN-ZB01 (optional) is attached
]
260 W
Dimensions (excluding protrusions) inch (mm)
Approx. 74 (W) x 5-5/16 (D) x 45-9/16 (H) (1880 x 135 x 1157)
Weight lbs. (kg)
Approx. 224.9 (102) (excluding the temporary stand)
Weight [PN-ZB01 (optional)] lbs. (kg)
Approx. 1.102 (0.5)
*1 Cannot be used simultaneously.
*2 Does not support plug and play.
*3 Temperature condition may change when using the monitor together with the optional equipments recommended by SHARP.
In such cases, please check the temperature condition specied by the optional equipments.
*4 In addition, check the requirements of the computer and other devices to be connected, and make sure that all requirements are satised.
*5 When AUTO INPUT CHANGE is set to OFF.
*6 When STANDBY MODE is set to STANDARD. When STANDBY MODE is set to LOW POWER: 0.5 W
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specication changes for product improvement
without prior notice. The performance specication gures indicated are nominal values of production units. There may be some deviations from
these values in individual units.