![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/4c/84cb60f3-e8eb-4021-8606-73ca7e146dd7/84cb60f3-e8eb-4021-8606-73ca7e146dd7-bg1f.png)
29
E
Specications
n
Product Specications
Model PN-T322B
LCD component
32" Class [31-1/2 inch (80 cm) diagonal] TFT LCD
Max. resolution (pixels)
1366 x 768
Max. colors
Approx. 16.77 million colors
Pixel pitch
0.511 mm (H) × 0.511 mm (V)
Viewing angle
176° right/left/up/down (contrast ratio ≥ 10)
Screen active area inch (mm)
27-7/16 x 15-7/16 (697.7 x 392.3)
Computer input signal
Digital (DVI 1.0 standard-compliant), Analog RGB (0.7 Vp-p) [75
Ω
]
Sync signal
Horizontal/vertical separate (TTL: positive/negative), Sync-on-green,
Composite sync (TTL: positive/negative)
Video color system
NTSC (3.58MHz)/NTSC (4.43MHz)/PAL/PAL-60/SECAM
Plug and play
VESA DDC2B
Power management
VESA DPMS, DVI DMPM
Input terminals Digital
HDMI x 1
DVI-D 24 pin (HDCP compatible) x 1
Analog
Mini D-sub 15 pin, 3 rows x 1
Composite video
RCA pin x 1
*
1
Component
RCA pin
(Y, Cb/Pb, Cr/Pr) x 1 *
2
Audio
3.5 mm mini stereo jack x 1
RCA pin (L/R) x 1
*
1
Serial (RS-232C)
D-sub 9 pin x 1
USB ash drive x 1 (for slideshow)
Output terminal
Audio
3.5 mm mini stereo jack x 1
Speaker output 8 W + 8 W
Touch Panel
Detection method Infrared camera method
Detection area inch (mm)
27 x 15 (685.7 x 380.3)
PC connector USB (1.1 compliant)
Power supply Supplied from USB
Position accuracy
inch (mm)
±1/4 (±6)
Power requirement AC 100 V - 240 V, 50/60 Hz
Operating temperature
*
3
41°F to 95°F (5°C to 35°C)
Operating humidity 20% to 80% (no condensation)
Power consumption
(input signal waiting mode
*
4
/ standby mode)
82 W
(0.9 W / 0.9 W)
Dimensions (excluding protrusions) inch (mm)
Approx. 30-1/4 (W) x 2-7/16 (D) x 18-1/8 (H) (769 x 62 x 461)
Weight lbs. (kg)
Approx. 24.3 (11)
*1 Uses the provided conversion cable (for AV video).
*2 Uses the provided conversion cable (for AV component).
*3 Temperature condition may change when using the display together with the optional equipments recommended by SHARP.
In such cases, please check the temperature condition specied by the optional equipments.
*4 D-SUB input (factory default setting)
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specication changes for product improvement
without prior notice. The performance specication gures indicated are nominal values of production units. There may be some deviations from
these values in individual units.