A SERVICE OF

logo

12- ENG
A08987
1. Shut off the pressure washer
and turn off the water supply.
2. Disconnect spark plug wire
to
ensure the unit will not start while
performing maintenance.
3. Pull trigger on gun handle
to
relieve any water pressure.
4. Disconnect the wand from the
gun.
5. Remove the nozzle from the
end of the wand with the 2mm
hex key provided as shown in Fig.
11.
6. Clean the nozzle using the
nozzle cleaner provided or a
straightened paper clip. Insert
into the nozzle end and work
back and forth until obstruction is
removed. (see Fig. 12)
7. Direct water supply into nozzle
end to backflush loosened particles
for 30 seconds. (see Fig. 13)
8. Reconnect spark plug wire
9. Reassemble the nozzle to
the wand. Tighten securely to
prevent leaks.
10. Reconnect wand to gun
and
turn on water supply.
11. Start pressure washer
and
place wand into high pressure
setting to test.
Fig. 11
Fig. 12
Fig. 13
HOW TO CLEAN THE WATER
INLET FILTER
This screen filter should be checked
periodically and cleaned if necessary.
1. Remove
filter
by
grasping
end and
removing it
from water
inlet of pump
as shown in Fig. 14.
2. Clean filter by flushing it with
water on both sides.
3. Re-insert filter
into water inlet
of pump. NOTE: Cone side faces
out.
NOTE: Do not operate pressure
washer without filter properly installed.
Filter Screen