A SERVICE OF

logo

19
FWD-S42H1
(b) Power On Batch
Syntax Header Category Function Data1 Data2 Data3 Check Sum
Control 0x8C 0x00 0x85 0x03 Input Select Code Volume Code 0xXX
Table (1-a)[a] Table (1-a)[b]
Syntax Header Category Function Data1 Data2 Check Sum
Enquiry 0x83 0x00 0x85 0xFF 0xFF 0xXX
Answer Header Answer Check Sum
Control 0x70 0x00 0x70 Completed
0x70 0x01 0x71 Limit Over
0x70 0x02 0x72 Limit Under
0x70 0x03 0x73 Command Canceled
Answer Header Answer Return to Data Size Data2 Data3 Check Sum
Enquiry 0x70 0x00 0x03 Input Select Code Volume Code 0xXX
Table (1-a)[a] Table (1-a)[b]
Code Table (1-a)
Input Select [a]
*2
0x08 HD15 RGB
0x09 HD15 YUV
0x0E Option RGB
0x0F Option COMPONENT
0x20 DVI
0x30 VIDEO
0x31 S-VIDEO
0x84 Option Digital1 (HDMI1/SDI)
0x85 Option Digital2 (HDMI2)
Volume [b] 0x00-0x64
Code Table (1-b)
[a]Function [b]Range/Switch code Command
Control Enquiry Standby Power On
0x85 Power On Batch Yes No Enable Control/Disable
*1 Whenthiscontrolcommandisreceived,thepowerofasetwillbeturnedonrst.
*2 Input Select setting, Auto Signal Detect becomes Disable. When Option Slot is connected, Option command is Enable.