Main Screen
SET PSI 0
ACTUAL PSI 0
The Main Screen is the default screen for
the control system at sprayer startup.
Pressing the #2 key switches between PSI, Bar, and MPa units of
measure. Press the #1 key to scroll through the remaining menu
screens.
L-SET PSI 0
ACTUAL PSI 0
(A) Pump Only - The “L-” before the “Set
PSI” text on the Main Screen indicates
that the two Component Pumps are linked.
i
For sprayers equipped with an nine-language
Control Display:
Pressing the #2 key at the Main Screen switches
between PSI, Bar and MPa units of measure.
Pressing the #3 key at the Main Screen changes
the language of the text on the display. There are
a total of nine languages available. Each time the
#1 key is pressed, a dierent language will appear.
The languages, in order of appearance, are: English,
Spanish, Dutch, Danish, Swedish, German, French,
Italian, and Portuguese.
Vis-Comp (Viscosity Compensation) Screen*
VIS-COMP -
1%
NEXT-1 +2 -3
TheVis-Compscreenonthe(B)pump
allows the user to see and/or adjust slight
dierences in viscosity between the (A) pump material and the (B)
pump material.
Pressing the #2 key will increase the spraying ratio in increments of
1% (up to 5%). Pressing the #3 key will decrease the spraying ratio
in increments of 1% (up to 5%). Pressing the #4 key will increase the
ratio by increments of .250.
Status Screen*
STATUS = LINKED
LINK-2 UNLINK-3
The Status Screen shows the link status of
the (A) pump and (B) pump.
STATUS = UNLINKED
LINK-2 UNLINK-3
When turning the system on, the two
pumps will automatically be linked, which
means the (A) pump is controlled by the (B) pump.
When the Status Screen is showing, pressing the #3 key will unlink
the two pumps, and the (A) pump and (B) pump will operate
independently and the (A) pump control display keys will be enabled.
If the pumps have been unlinked, pressing the #2 key will link the two
pumps back together, and the (A) pump will now be controlled by
the (B).
Alarm Range Screen*
ALARM RANGE
+/- 750 PSI
The Alarm Range Screen allows the
user to adjust the allowable pressure
discrepancy between the (A) and (B) pumps.
Pressing the #2 key will increase the allowable pressure discrepancy
by 50 psi. Pressing the #3 key will decrease the allowable pressure
discrepancy by 50 psi. The range is 250 psi - 1000 psi.
Alarm Status Screen*
ALARM STATUS: OFF
ON-2 OFF-3 EXT-4
The Alarm Status Screen allows the user
toswitchONorOFFtheinternalalarm
that alerts the user to a non-allowable pressure imbalance.
Pressingthe#2keywillturnthealarmON.Pressingthe#3keywill
turn the alarm OFF.
i
If a pressure imbalance is detected in the system
with the alarm status set to ON, the system will
automatically shut down and the display will show
a PSI Imbalance. Refer to Control Display Error
Messages.
Total Cycles Screen*
TOTAL CYCLES
SELECT-4MENU-1
The Total Cycles Screen shows the total
number of piston cycles a component
pump has performed during its lifetime.
CYCLES XXXX
RESET-3MENU-1
Pressing the #3 key will reset the cycle
counttozero.Pressingthe#1keywill
bring the control panel back to the Main Screen.
Job Cycles Screen*
JOB CYCLES
SELECT-4MENU-1
TheJobCyclesScreenshowsthetotal
number of piston cycles a component
pump performs during a spray job.
CYCLES XXXX
RESET-3MENU-1
Pressing the #3 key will reset the cycle
counttozero.Pressingthe#1keywill
bring the control panel back to the Main Screen.
Unit Serial # Screen
UNIT SERIAL #
SELECT-4MENU-1
The Unit Serial # screen shows the
sprayers serial number.
SER # XXXXXXXXXX
MENU-1
To select the Unit Serial # screen, press
the #4 key.
Timers Screen
TIMERS
SELECT-4MENU-1
The Timers screen shows the total time
the sprayer has been turned on as well
as the total time the sprayer has been
running (pumping).
ON TIME
RUN TIME
XXXX
XXXX
To select the Timers screen, press the #4
key.
Job Timers Screen
JOB TIMERS
SELECT-4MENU-1
TheJobTimersscreenallowstheuserto
resetthe“ONTIME”and“RUNTIME”to
track time on specic jobs.
JOB ON X
RESET-3MENU-1
JOB RUN X
RESET-3MENU-1
ToselecttheJobTImersscreen,press
the#4key.“JOBON”screenwillappear.
Press #3 to reset. Press #1 to continue
to“JOBRUN”screen.Press#3toreset.
Press #1 to scroll through the remaining
menu screens.
Service Time Screen
SERVICE TIME
SELECT-4MENU-1
The Service Time screen allows the user
to set a service time interval (in hours).
Below the set time, the screens shows the
current amount of hours on the sprayer
since the last activation of the service
timer. To select the Service Timer screen,
press the #4 key.
SERVICE @ XX
RUN HOURS XX
To set the service time, press the #2 (up)
and/or the #3 (down) keys to the desired
time (run hours will increase/decrease in
increments of 1 for each time you press
a key).
When the service time interval is set and met by the run hours, the
display will show a “Service Required” screen. The pump will remain
functional. To return to the Main Screen, press the #1 key. Doing so
will reset the “Service @” and “Run Hours” displayed on the Service
Screen back to 0.