© Titan Tool Inc. All rights reserved. 15
Xact Digital Control System Error Messages
The following error message screens appear whenever the Xact
Digital Control System detects a problem with the sprayer. Once a
problem occurs and the error message appears, the sprayer will shut
down.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer before
servicing!
Check Paint Screen (E1)
The Check Paint screen appears when the
pump pressure drops to a very low level
and the pressure control knob has not been adjusted. Check the
paint level and rell. Restart the sprayer by following the “Painting”
procedure in the Operation section of this manual.
Check Transducer Screen (E2)
The Check Transducer screen appears
when the transducer has become
disconnected or is defective. Take the sprayer to a Titan authorized
service center for repair.
Check Motor Screen (E3)
The Check Motor screen appears when the
motor or motor sensor is defective. Take
the sprayer to a Titan authorized service center for repair.
Low Voltage Screen (E4)
The Low Voltage screen appears when the
sprayer shuts down because of low input
voltage. Check the power supply and correct the problem. Restart
the sprayer by following the “Painting” procedure in the Operation
section of this manual.
High Motor Temperature Screen (E5)
The High Motor Temperature screen
appears when the temperature of the
motor has risen too high. Take the sprayer to a Titan authorized
service center for repair.
High Control Temperature Screen (E6)
The High Control Temperature screen
appears when the temperature of the Xact
Digital Control System has risen too high. Take the sprayer to a Titan
authorized service center for repair.
High Load Check Mechanism Screen (E7)
The High Load Check Mechanism screen
appears when the sprayer shuts down
because of high current or when the sprayer goes into current fold
back mode.. Take the sprayer to a Titan authorized service center for
repair.
Exceeded Pressure Limit Screen (E8)
The Exceeded Pressure Limit screen
appears when the sprayer pressure
exceeds 3300 PSI / 22.8 MPa. Take the sprayer to a Titan authorized
service center for repair.
Communication Error Screen (E9)
The Communication Error screen appears
when the Xact Digital Control System loses
communication with the control panel. Take the sprayer to a Titan
authorized service center for repair.