16
CORDED MODELS: APS 1012
Weight: 26.4 lbs.
INVERTER
Continuous power (@ 20° C): 1000 W
Surge power (5 seconds): 2000 W
Efficiency (Full Load): 88%
Minimum DC Fuse Rating: 225A
DC Input Current @ Nominal V DC
Full Load 95 A
No Load 2.2 A*
Nominal Input Volts: 12 VDC
DC Input Voltage Range: 10-15 VDC
Nominal Output Volts: 120 VAC ±5%
Nominal Output Frequency: 60 Hz ±.3%
BATTERY CHARGER
Charging Capacity DC: 10 A**
Maximum Cable Length 2 ft.
Acceptance Volts VDC: Selectable 14.4 V**/14.2 V Wet**/Gel
Float Volts VDC (w/gel): 13.3 V (13.6 V)
Input Voltage AC: 120 V
Input Current AC: 1.4 A**
LINE VAC OPERATION
Minimum Input AC Volts: Selectable 75**,85, 95, or 105 VAC
Maximum Input AC Volts
(Continuous, Charger at Maximum): Selectable 135** or 145 VAC
Maximum Input Current
(Continuous, Charger at Maximum): 12 A
Input Frequency: 60 Hz ±10%
Maximum Output AC (Continuous): 8.3 A
Automatic Transfer Time: 4-6 ms
* Load sense can reduce this to 1/30 of the listed current. **Factory default setting.
Specifications
(Corded Models)
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 16