reboot of the storage controller at a future time. In the event the management/CIFS VIF needs to be
created after the initial setup of the FAS2050, please refer to the Data ONTAP® Software Setup Guide
for
irections in rerunning the setup process for the storage controller. d
1. For each NetApp controller, open NetApp FilerView® and click Network->Add Virtual Interfaces.
2. Name the new VIF.
3. Select the two network interfaces that will make-up the NFS VIF.
4. For Trunk Mode press the drop down arrow and select Multiple.
5. For Load Balancing press the drop down arrow and select IP.
6. Click Apply.
Figure 3) AS2050 NFS VIF setup –Create Virtual Interface. F
1. At the Manage Network Interfaces screen, click on Modify for the new VIF that was created in the
previous steps.
2. At the Modify Network Interfaces screen enter a private IP Address that will be used for ESX host
NFS connectivity and then enter the Netmask and click Apply.
3. At the Manage Network Interfaces screen click on Up for the new VIF in order to activate it.