D-6 DRAFT DAMPER
A Draft Damper included with the stove must be
installed in the first straight section of pipe exit-
ing the stove before the stove pipe is connected
and the cook stove is used.
1. Drill two 1/4” holes centered on either side of
the pipe section 6” from the top end of the pipe
(figure 6).
2. Remove the handle from the damper then slide
the damper into the pipe.
3. Align the damper with the holes drilled in step
1 and insert the handle through the holes and
the damper.
NOTE: This damper is necessary for the proper
operation of the stove and to meet EPA
emissions requirements for heating appli-
ances. It MUST be installed before use.
(NO EXCEPTIONS)
Proper clearances must be maintained for ad-
equate air circulation. Adequate ventilation must be
provided while operating this stove.
1. The stove must be placed on solid con-
crete, solid masonry, or when installed on a
combustible floor, on a Underwriters Labora-
tory Listed floor protector, such as Hy-C or
Imperial Model UL 5659. The base must ex-
tend at least 18” beyond the front of the hearth,
18” to the sides of the stove, and must extend
under the stove pipe if it is elbowed towards a wall
(see figure 2 and consult local building codes and
fire protection ordinances.)
Fig. 2 – Minimum Clearance Dimensions from Combustible Surfaces
COMBUSTIBLE
CONSTRUCTION
ACCORDING TO
NFP A 211
FLOOR
PROTECTOR
DASHED LINE SHOWS
HORIZONTAL CHIMNEY
CONNECTOR AND
ADDITIONAL FLOOR
PROTECTION REQUIRED
BACKWALL
56"
(TOP VIEW)
18"
18"
36"
36"
59"
1
8
"
SIDEWALL
COMBUSTIBLE
CONSTRUCTION
ACCORDING TO
NFPA 211
2. The stove must have its own flue. DO NOT CON-
NECT THIS UNIT TO A CHIMNEY FLUE
SERVING OTHER APPLIANCES.
3. After observing the clearances to combus-
tible materials (figure 2 & 3), locate your floor
protector accordingly (figure 2) and careful-
ly place the stove in your selected location.
Install stove pipe, elbows, and thimble as
required, utilizing either a recently cleaned and
inspected 6” masonry chimney or a 6” i.d. listed
chimney. Maximum 64 square inches.
Continued on page 4
6"/15.25 cm
Draft Damper
(must be installed
before use — NO
EXCEPTIONS!)
LOCATING STOVE
Fig. 1
Draft Damper
Installation