48
TROUBLESHOOTING cont...
High Limit hardware circuit tripped.
• Add cold water in spa and let heater cool
down.
• Reset spa pack using current breaker.
System hasn’t detected any current change
when turning on or off Pump 1.
• Make sure Pump 1 is connected properly.
• Manually change output status (on/off) of
Pump 1 and cycle through all possible states
(i.e. low and high speeds)
• Reset spa pack.
• If error does not clear, call your local dealer
and schedule a service call.
System hasn’t detected any current change
when turning on or off Pump 2.
• Make sure Pump 2 is connected properly.
• Manually change output status (on/off) of
Pump 2 and cycle through all possible states
(i.e. low and high speeds)
• Reset spa pack.
• If error does not clear, call your local dealer
and schedule a service call.
System hasn’t detected any current change
when turning on or off Pump 3.
• Make sure Pump 3 is connected properly.
• Manually change output status (on/off) of
Pump 3 and cycle through all possible states
(i.e. low and high speeds)
• Reset spa pack.
• If error does not clear, call your local dealer
and schedule a service call.