FOR THE ELECTRICIAN
ELECTRICAL REQUIREMENTS
A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical supply IS
required (time delay fuse or circuit breaker is recommended).
It is recommended that a separate circuit, serving only this
appliance, be provided. DO NOT use an extension cord.
ELECTRICAL GROUND IS REQUIRED ON THIS
APPLIANCE.
RECOMMENDED
GROUNDING MtHOD
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
For your personal safety, this appliance must be grounded.
This appliance is equipped with a power supply cord having a
3-prong grounding plug. To minimize possible shock hazard,
the cord must be plugged into a mating 3-prong grounding
type wall receptacle, grounded in accordance with the Natlonal
Electrical Code and local codes and ordinances. If a mating
wall receptacle is not available, it is the personal responslbillty
and obligation of the customer to have a properly grounded
3-prong wall receptacle installed bv a qualified electrician
See Figure 6
3-PRONG
GROUNDING TYPE
WALL RECEPTACLE
II
II I
NG
NDING
\ POWER SUPPLY
CORD
FIGURE 6
ALTERNATE
GROUNDING METHOD
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
If changing and properly grounding the wall recepta-
cle
IS
lmposslble and where local codes permit
(consult your electrlcal inspector). a temporary
adapter may be plugged into the existing 2-prong wall
receptacle to mate with the 3-prong power supply
cord. See Figure 7. THIS, HOWEVER, IS NOT RE-
COMMENDED.
If this IS done, you musT connect the grouncllng eyelet on the
adapter to the wall receptacle cover plate screw and from this
same screw, you must connect a separate copper ground wire
(No 4 mlnimum) to a qrounded cold water pipe’ See Flgu:e
7 Do not ground to a gas supply pipe. Do not connect to
electrical supply until appliance IS permanently grounded.
-Cold water pipe must have melal contlnulty to electrIcal
ground and not be Interrupted by plastic rubber or other
electrIcally lnsulatlng connectors (including waler meter or
pump) wlthout addlng a lumper wire at these connectlons
GROUND ASSEMBLY
(ATTACH TO GROUNDED
COLD WATER PIPE)
ELECTRICALLY
GROUNDED COLD
WATER PIPE (REMOVE
GROUND WIRE (#4 i’llNlMUMl
/
K
GROUNDING
EYELET a
ASSEMBLY
1
i
POWER SUPPLY CORD
FIGURE 7
WALL
f
RECEPTACLE