5
EN
EN
The lid is difficult to open
Is the lid seal dirty or sticky?
If you still need help, please contact your local Service Force Centre.
Service or repair
In cases of breakdown or faults, your freezer must be serviced by an authorized Electrolux Service engineer.
Important! Under no circumstances should you attempt to repair the appliance yourself.
Technical Data
Climatic classification Ambient temperature limits
SN from +10°C to +32°C
N from +16°C to +32°C
ST from +18°C to +38°C
T from +18°C to +43°C
This appliance complies with the following EC Directives:
73/23/EEC of 19. 02. 1973 Low-Voltage Directive
89/336/EEC of 03. 05. 1989 (including Amendment Directive 92/31/EEC - EMC
Directive)
Model BNI280 BNI425 BNI525 BNI325 BNI225
ZFC326WB ZFC340WB ZFC350WB ZFC330WB ZFC321WB
Volume (gross) Litre 263 404 500 304 213
Volume (net) Litre 260 400 495 300 210
Height cm 87,6 87,6 87,6 87,6 87,6
Width cm 93,5 132,5 160 105 79,5
Depth cm 66,5 66,5 66,5 66,5 66,5
Weight net kg 44 56 66 49 39
Energy consumption
24 Stunden kWh/24 h 0,878 1,152 1,338 0,957 0,78
Freezing capacity kg/24 h 16 19 20 17 14
Hold-over time Hours 32 31 31 32 28
Rated power Watt 100 100 140 100 100
Voltage Volts 230 230 230 230 230
Climatic class SN-T SN-T SN-T SN-T SN-T