Control Port Operation HDSL2 for General Distribution Installation and Maintenance Practice
22 61223HDSL2L2-5B
Provisioning
The Provisioning menu (Figure 16) displays current settings. To change a particular option
setting (for example, “1” for DSX-1 Line Build Out) select the appropriate number, press
ENTER,
and the new menu will appear with a list of the available settings. To return to this screen
and/or the Main Menu, press
ESC. To re-deploy this unit, press D which will restore the factory
default settings to those shown in Table 6 on page 11.
Figure 16. Provisioning Screen
NOTE
DSX-1 Line Build Out is set to 0-133 feet. This option is set to
EXTERNAL if using a Kentrox shelf. Otherwise, the LBO option
should be set to zero (0).
NOTE
Shelf Alarm option is on the DDM+ and 3192 modules only.
Total Access 3000 H2TU-C Provisioning Menu
Two screens comprise the provisioning menu for the Total Access 3000 H2TU-C. Figure 17
illustrates the first page of the menu.
Press the
N (and ENTER) to move forward to the next screen. Figure 18 shows the remainder of
the Provisioning menu.
To return to the previous screen, press
P.
To return to the Main Menu, press
ESC.
Circuit ID:HNTSVLALHDSL2 03/01/05 09:29:45
Press ESC to return to previous menu
Provisioning
1. DSX-1 Line Buildout = 0-133 feet
2. DSX-1/DS1 Line Code = B8ZS
3. DSX-1/DS1 Framing = ESF
4. Forced Frame Conversion = Disabled
5. Smartjack Loopback = Enabled
6. Loopback Timeout = 120 Minutes
7. Latching Loopback Mode = T1 (Disabled)
8. DS1 TX Level = 0 dB
9. Span Power = Enabled
10. Customer Loss Indicator = AIS / CI
11. PRM Setting = AUTO
12. Loop Atten Alarm Thres = 30 dB
13. SNR Margin Alarm Thres = 04 dB
14. Remote Provisioning = Enabled
15. Shelf Alarm = Enabled
D. Restore Factory Defaults
Selection: