![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/3d/03df430e-4a5d-3df4-d960-a18623c223d9/03df430e-4a5d-3df4-d960-a18623c223d9-bg25.png)
TRACER 6000 Series Integrated System Manual Section 3 Engineering Guidelines
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 37
5. NETWORK MODULE INTERFACES
4xT1 Module
The 4xT1 network module has four T1 interfaces (through four RJ-45 ports) that provide the following
functions:
• ANSI T1.403 and AT&T
®
54016 and 62411 compliant
• AMI or B8ZS coding
• Extended Super Frame (ESF) and Super Frame (SF) framing support
• Manual line build out
• Network performance monitoring and reporting
• Test loopbacks (both line and link)
Table 10 provides the RJ-45 interface pinout for the 4xT1 network module.
Quad Ethernet Switch Module
The Quad Ethernet Switch module has four 10/100BaseTX interfaces (through four RJ-45 ports) that
provide the following functions:
• IEEE 802.3 and 802.3u compliant
• Auto MDI/MDIX crossover
• Back-pressure flow control on all full-duplex interfaces
• Link and activity LEDs for each port
Table 11 provides the RJ-45 interface pinout for the Quad Ethernet Switch module.
Table 10. 4xT1 Module RJ-45 Connector Pinout
Pin Name Description
1 R Transmit data (ring) towards the network
2 T Transmit data (tip) towards the network
3, 6-8 UNUSED —
4 R1 Receive data (ring) toward the network
5 T1 Receive data (tip) from the network
Table 11. Quad Ethernet Switch RJ-45 Connector Pinout
Pin Name Source Description
1 RX1 Attached Equipment Receive Positive
2 RX2 Attached Equipment Receive Negative
3 TX1 Module Transmit Positive
4, 5 Unused N/A —
6 TX2 Module Transmit Negative
7, 8 Unused N/A —