Meter Functions Audible Continuity ( )
IMPORTANT:
Turn the power
OFF on the test circuit
Select the
Audible Continuity
( ) range with the rotary
switch.
Insert:
Black lead in COM terminal.
Red lead in
V -
Ω
- RPM
terminal.
Connect one test probe to
each end of the circuit to be
tested.
Circuit complete, the meter
will beep continuously.
Circuit open, there is no beep
and the display shows to
“ I ” (over limit)
Meter Functions DC Current (A)
IMPORTANT :
All current measured
flows through the meter.
It is important that you do not:
Measure current greater than
600 Volts AC or DC, with
respect to ground.
Exceed 60 seconds when
measuring continuous
current between 1A-10A.
Allow five minutes for cool
down before continuing.
Select the
10A
range with the
rotary switch.
Insert:
Black lead in
COM
terminal.
Red lead in the
10A
terminal
IMPORTANT:
Turn OFF all power to the circuit
or disconnect the circuit from the
power source.
Connect:
The Red probe to the side of the
circuit closest to the power
source.
The Black probe to the side of the
circuit to ground.
Turn the power ON and test.
-
Note:
Current must always be
measured with the mete
r
test probes connected in
series, as described.