![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/11/411f54e2-c10f-46cb-993d-caaeb1e81e40/411f54e2-c10f-46cb-993d-caaeb1e81e40-bgf.png)
Operation
OVATION™ E-190WW User Manual Rev. 3 -11-
DMX Values
Channel Function Value Percent/Setting
Channel Function Value Percent/Setting
3 Strobe
010 ó 099
100 ó 109
110 ó 179
180 ó 189
Strobe (slow to fast)
No function
Lighting effect
No function
Set the DMX personality as follows.
1. Go to the SET main level.
2. Select the PERS programming level.
3. Select the desired personality: UNO (1-channel), DOS (2-channel),
or STD.P (3-channel).
· See the DMX Control section for the highest starting address you can select for each
personality.
· Make sure that the starting addresses on the various products do not overlap due to
the new personality setting.
DMX Control allows you to assign each product to a unique starting address on the DMX
controller. All products with the same starting address will respond in unison.
1. Select a DMX personality.
2. Set the running mode:
· Go to the RUN main level.
· Select DMX.
Note: For information on the SLAV option, see Master/Slave Mode
.
3. Set the starting address:
· Go to the ADDR main level.
· Select the starting address D.001–D.512.
The highest recommended starting address for each DMX mode is as follows:
DMX
DMX
DMX
DMX
DMX
DMX
This setting controls how the product responds when the DMX signal is lost.
1. Go to the SET main level.
2. Select the DERR programming level.
· Select BLAK to turn off the LEDs when the signal is lost.
· Select SAVE to use the last command programmed when the signal is lost.