![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/e7/6e76f70f-8c9a-9534-ddfa-0bfbc9cae8b3/6e76f70f-8c9a-9534-ddfa-0bfbc9cae8b3-bg16.png)
22 Installation (for qualified installers only)
© Travis Industries 4080214 100-01182_003
Approved Vent
• Rear vent configurations use 8" diameter Simpson Dura-Vent Model GS vent.
• Top vent configurations use 8" or 6-5/8" diameter Simpson Dura-Vent Model GS vent. If using
6-5/8" diameter vent, attach the 8" to 6-5/8" reducer (Travis part # 98900165) to the fireplace.
6-5/8" Diameter Vent
Reducer - # 98900165
Vent Installation
• Slide the vent sections together and turn 1/4 turn until the sections lock
in place.
• Screws are not required to secure the vent. However, three screws may
be used to secure vent sections together if desired.
• High temperature sealant is recommended at the appliance starter
section connection (use high-temperature silicone or Mill-Pac®).
• If disassembly is required, at time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high temperature sealant to the
joints of the affected sections.
• Horizontal sections require a 1/4" rise every 12" of travel
• Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)