A SERVICE OF

logo

8 308149
Installation
(AIR-POWERED PUMPS)
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawings.
Accessories are available from your Graco distributor.
If you supply your own accessories, be sure they are
adequately sized and pressure-rated to meet the
system’s requirements.
The Typical Installation shown in Fig. 3 is only a guide
for selecting and installing system components and
accessories. Contact your Graco distributor for assis-
tance in designing a system to suit your particular
needs.
01177A
Fig. 3
KEY
A Pump
B 200 Liter (55 Gallon) Air-Powered Ram
C Pump Runaway Valve
D Air Line Lubricator
E Bleed-Type Master Air Valve
(required, for pump)
F Pump Air Regulator
G Air Manifold
H Electrically Conductive Air Supply Hose
J Air Line Filter
K Bleed-Type Master Air Valve (for accessories)
L Fluid Regulator
M Fluid Drain Valve (required)
N Electrically Conductive Fluid Supply Hose
P Fluid Shutoff Valve
R Gun/Valve Swivel
S Airless Spray Gun or Dispensing Valve
T Ram Air Regulator
Y Ground Wire (required, see page 7 for
installation instructions)
A
B
D
E
F
G
H
JK
M
Y
MAIN AIR LINE
R
S
T
L
M
N
P
R
S
FLUID HEADER PIPE
(3 in. Diameter)
LP
M
N
C