Hardware Release Notes
6.17 RFnn DSSI Disk Devices and Controller Memory Errors
Table 6–2 Supported Microcode Revision Levels
Device Type Minimum Level with Supported Microcode
RF31T T387E
RF31T+ T387E
RF35 T392D
RF35+ T392D
RF36 V427P
RF73 T392D
RF74 V427P
To display the microcode revision level of your DSSI disk devices, perform the
following steps:
1. Log in to the SYSTEM account or another account that has the CMKRNL,
DIAGNOSE, and SYSPRV privileges.
2. Enter the following commands:
$ SET PROCESS /PRIVILEGE=(DIAGNOSE,CMKRNL,SYSPRV)
$ SHOW DEVICE FYA0:
On VAX systems, if the SHOW DEVICE command produces an error, enter
the following commands:
$ RUN SYS$SYSTEM:SYSGEN
SYSGEN> CONN FYA0/NOADAP
SYSGEN> ^Z
On Alpha systems, if the SHOW DEVICE command produces an error, enter
the following commands:
$ RUN SYS$SYSTEM:SYSMAN
SYSMAN> IO CONNECT FYA0: /NOADAP
SYSGEN> ^Z
The following is an example of the display produced by the RF_VERS utility:
Program Name: RF_VERS
Revision Level: V1.2s
NOTICE: This program does not currently support the RF72 or any
HSDxx controllers. See next version for support.
DSSI disks currently on this system as seen by RF_VERS
Device Node Status Hardware Firmware
Name Name Type Version
_$22$DIA7: R4JL2I mounted RF73 T387A
_$22$DIA6: R4I0BG mounted RF73 T387A
_$22$DIA8: R4XLWE mounted RF73 T387A
_$22$DIA2: R4FCZK mounted RF73 T387A
_$22$DIA3: R4CKCG mounted RF73 T387A
_$22$DIA4: R4ZKUE mounted RF73 T387A
_$22$DIA9: R4GYYI mounted RF73 T387A
_$22$DIA1: R4XRYI mounted RF73 T387A
Hardware Release Notes 6–17