4: Using DeviceInstaller
Device Details
Settings
Description
Configurable field. Information about the Micro125.
Double-click the field, type in the value, and press Enter to complete. This
description or comment is not visible on other PCs or laptops using
Non-configurable field. Displays the Micro125’s device family as Micro125.
Non-configurable field. Displays the device type as Micro125.
Non-configurable field. Displays the Micro125’s ID embedded within the
Non-configurable field. Displays the Micro125’s hardware (or MAC)
address.
Non-configurable field. Displays the firmware currently installed on the
Extended Firmware
Version
Non-configurable field. Displays the full version nomenclature of the
firmware.
Non-configurable field. Displays the Micro125’s status as online, offline,
unreachable (the Micro125 is on a different subnet), or busy (the Micro125
is currently performing a task).
Non-configurable field. Displays the Micro125’s current IP address. To
change the IP address, click Assign IP on the DeviceInstaller menu bar.
Obtained
Displays “Dynamically” if the device automatically received an IP address
(e.g., from DHCP). Displays “Statically” if the IP address was configured
manually. If the IP address was assigned dynamically, the following fields
appear:
Obtain via DHCP with value of True or False.
Obtain via BOOTP with value of True or False.
Obtain via RARP with value of True or False
Obtain via Auto IP with value of True or False
Non-configurable field. Displays the Micro125’s current subnet mask.
Non-configurable field. Displays the Micro125’s current gateway.
Number of COB
partitions supported
Non-configurable field. Displays the number of COB partitions supported.
Non-configurable field. Displays the number of ports on the Micro125.
Non-configurable field. Displays 1-65s, the Micro125’s TCP keepalive
value. The default setting is 45.
Non-configurable field. Indicates whether Telnet is enabled on this
Micro125.
Non-configurable field. Displays the Micro125’s port for Telnet sessions.
Non-configurable field. Displays the Micro125’s port for Web-Manager
configuration.
Maximum Baud Rate
Supported
Non-configurable field. Displays the Micro125’s maximum baud rate.
Note: the Micro125 may not currently be running at this rate.
Micro125 User Guide 16