5: Configuration Using Web Manager
Advanced
Advanced Settings Description
(secs)
When the unit communicates with another device on the network, it
adds an entry into its ARP table. ARP Cache timeout defines the
number of seconds (1-600) before it refreshes this table.
TCP Keepalive time defines how many seconds the unit waits during
an inactive connection before checking its status. If the unit does not
receive a response, it drops that connection. Enter a value between
0 and 60 seconds. 0 disables keepalive. The default setting is 45.
Select Disable to disable entry into the monitor mode using the 'yyy'
or 'xx1' key sequence at startup. This field prevents the unit from
entering monitor mode by interpreting the stream of characters that
are received during the device server's initialization at startup.
This option allows the configuration of the web server port number.
The valid range is 1-65535. The default port is 80.
Not applicable for this product.
The Maximum Transmission Unit (MTU) is the largest physical
packet size a network can transmit for TCP and UDP. Enter between
512 and 1400 bytes. The default is 1400 bytes.
timeout (ms)
The desired TCP re-transmission timeout value. If the ACK is not
received for a packet sent from the Micro125 device, then the unit
will retransmit the data. The valid range is 500-4000 msec.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Host List Configuration
The Micro125 scrolls through the host list until it connects to a device listed in the host list
table. After a successful connection, the unit stops trying to connect to any others. If this
connection fails, the unit continues to scroll through the table until the next successful
connection.
The host list supports a minimum of 1 and a maximum of 12 entries. Each entry contains an
IP address and a port number.
Note: The host list is disabled for Manual and Modem Mode. The unit does not accept a data
connection from a remote device when the hostlist option is enabled.
To configure the Micro125’s host list:
1. On the main menu, click Hostlist.
Micro125 User Guide 24