Diagnostic Error Code FRU/Action
000-250-XXX
BIOS APM failure
1. Flash the system. See “Updating
(flashing) BIOS from a disc” on page
656
2. System board
000-270-XXX
BIOS ACPI failure
1. Flash the system. See “Updating
(flashing) BIOS from a disc” on page
656
2. System board
001-000-XXX
System Test Passed
No action
001-00X-XXX
System Error
System board
001-01X-XXX
System Error
System board
001-024-XXX
System Addressing test failure
System board
001-025-XXX
System Checksum Value error
1. Flash the system. See “Updating
(flashing) BIOS from a disc” on page
656
2. System board
001-026-XXX
System FLASH data error
1. Flash the system. See “Updating
(flashing) BIOS from a disc” on page
656
2. System board
001-027-XXX
System Configuration/Setup error
1. Run Setup
2. Flash the system. See “Updating
(flashing) BIOS from a disc” on page 656
3. System board
001-032-XXX
System Device Controller failure
System board
001-034-XXX
System Device Buffer Allocation failure
1. Reboot the system
2. Flash the system. See “Updating
(flashing) BIOS from a disc” on page 656
3. Run memory test
4. System board
001-035-XXX
System Device Reset condition detected
System board
001-036-XXX
System Register error
System board
001-038-XXX
System Extension failure
1. Adapter card
2. System board
001-039-XXX
System DMI data structure error
1. Flash the system. See “Updating
(flashing) BIOS from a disc” on page
656
2. System board
56 Hardware Maintenance Manual