Diagnostic Error Code FRU/Action
001-040-XXX
System IRQ failure
1. Power-off/on system and re-test
2. System board
001-041-XXX
System DMA failure
1. Power-off/on system and re-test
2. System board
001-195-XXX
System Test aborted by user
Information only
Re-start the test, if necessary
001-196-XXX
System test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
001-197-XXX
System test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
001-198-XXX
System test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Flash the system and retest. See
“Updating (flashing) BIOS from a disc”
on page 656
3. Go to “Undetermined problems” on page
80
001-199-XXX
System test failed, cause unknown
1. Go to “Undetermined problems” on page
80
2. Flash the system and re-test
3. Replace component under function test
001-250-XXX
System ECC error
System board
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System DMA error
System board
001-260-XXX
001-264-XXX
System IRQ error
System board
001-268-XXX
System IRQ1 failure
1. Device on IRQ1
2. System board
001-269-XXX
System IRQ2 failure
1. Device on IRQ2
2. System board
001-270-XXX
System IRQ3 failure
1. Device on IRQ3
2. System board
Chapter 7. Symptom-to-FRU index 57