![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/93/d93c5391-ea56-40c7-a3e2-1b24b31e485c/d93c5391-ea56-40c7-a3e2-1b24b31e485c-bg43.png)
Diagnostic Error Code FRU/Action
011-000-XXX
Serial port Interface Test Passed
No action
011-001-XXX
Serial port Presence
1. Remove external serial device, if
present
2. Run setup, enable port
3. System board
011-002-XXX
011-003-XXX
Serial port Timeout/Parity error
System board
011-013-XXX
011-014-XXX
Serial port Control Signal/Loopback test
failure
System board
011-015-XXX
Serial port External Loopback failure
1. Wrap plug
2. System board
011-027-XXX
Serial port Configuration/Setup error
1. Run Setup, enable port
2. Flash the system. See “Updating
(flashing) the BIOS from a disc” on page
380
3. System board
011-03X-XXX
011-04X-XXX
Serial port failure
System board
011-195-XXX
Serial port Test aborted by user
Information only
Re-start the test, if necessary
011-196-XXX
Serial port test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
011-197-XXX
Serial port test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
011-198-XXX
Serial port test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Flash the system and re-test. See
“Updating (flashing) the BIOS from a
disc” on page 380
3. Go to “Undetermined problems” on page
80
Chapter 7. Symptom-to-FRU index 61