Installation (for qualified installers only) 15
Travis Industries 100-01142 4050114
Approved Venting Configurations with a Vertical Termination
Remove the diffuser plate (see Diffuser Plate Removal on page 12)
Two 90° elbows or two 45° offsets may be used (after the initial 90° elbow)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
5 feet
10 feet
0 feet
0 feet
2' (max)
0 feet
Restrictor Position # 7
Remove Diffuser Plate
20 feet
30 feet
31' (max)
15 feet
25 feet
2' (max)
5 feet
10 feet
0 feet
20 feet
30 feet
31' (max)
15 feet
25 feet
Restrictor Position # 5
Remove Diffuser Plate
Natural Gas
5 feet
10 feet
0 feet
0 feet
3' (max)
0 feet
Restrictor Position # 6
Remove Diffuser Plate
20 feet
30 feet
31' (max)
15 feet
25 feet
3' (max)
5 feet
10 feet
0 feet
20 feet
30 feet
31' (max)
15 feet
25 feet
Restrictor Position # 5
Remove Diffuser Plate
Propane (LP)