A SERVICE OF

logo

SCSI Description
5-42 Maxtor Atlas 10K III
Table 5-53 lists the mode pages that are supported by the drive. An initiator can
change these pages by supplying them, with the desired changes included, in the
MODE SELECT commands data-out buffer transfer.
The initiator should first use a MODE SENSE command to read the appropriate pages
and leave non-changeable values as read when the initiator subsequently writes the
changeable pages with the MODE SELECT command. If a non-changeable field
contains an invalid value, the drive returns a CHECK CONDITION status.
Initiator-Changeable Mode Pages
NOTES:
1. This page is not supported by the SCSI-1/CCS Operating Mode.
2. The Notch and Partition page is changeable but NOT savable.
3. XOR is currently disabled and page is not changeable.
00h Unit Attention Control Page
Unit Attention report-
ing (enables or dis-
ables)
4
01h
Read-Write Error Recovery Page
Medium Access Error
recovery and report-
ing procedures for
READ and WRITE
commands
12
02h Disconnect-Reconnect Page
Bus behavior during
data transfers
16
07h
1
Verify Error Recovery Page
Medium Access Error
recovery and report-
ing procedures for the
VERIFY command
12
08h
1
Caching Page Cache policy 20
0Ah
1
Control Mode Page
Command processing
policy
12
0Ch
Notch and Partition Page
2
Drive geometry re-
porting
24
10h XOR Control Page
Controls XOR operat-
ing parameters
24
19h Port Control Page
Defines port control
parameters
8
1Ah Power Condition Page
Enable and set time
intervals for Idle and
Standby modes
12
1Ch
1
Information Exceptions Control
Page and operations of specific
informational exception condi-
tions.
Defines methods to
control reporting
12
39h Maxtor-Unique Page 22